bounceReset (power-cycle) the camera over GigE without physically unplugging it.
Sends the GenICam DeviceReset command, which reboots the camera to its
power-up state. By default the tool waits for the camera to reappear on
the network before exiting.
# Reset by IP, wait for reboot
ag-cam-tools bounce -a 192.168.0.201
# Reset by serial, skip waiting
ag-cam-tools bounce -s PDH016S-001 --no-wait
# Reset with a longer timeout
ag-cam-tools bounce -a 192.168.0.201 --timeout 60
| Flag | Description |
|---|---|
-s, --serial <serial> |
Match camera by serial number |
-a, --address <address> |
Connect by camera IP |
-i, --interface <iface> |
Restrict to this NIC |
--no-wait |
Exit immediately after issuing the reset |
--timeout <seconds> |
Max seconds to wait for the camera to come back (default: 30) |
--no-wait is not given, the tool polls the network until the camera
reappears or the timeout expires.